Files
MCM/A题/AAA常用/最终内容/p2_response_4_1.md
2026-02-16 21:52:26 +08:00

2 lines
9.8 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{"FIGURE_REQUIREMENTS_EXTRACTED":{"default_used":true,"baseline_scenario":{"name":"S0 Baseline (6-hour alternating usage; Ta=25°C; includes one poor-signal navigation hour)","reason":"Used as the reference case for ΔTTE in scenario comparisons and for baseline TTE/UQ reporting.","source_locator":"[Source: Numerical Output (3); Keyword/Table/Section: SCENARIO_TTE_TABLE_v1 row 'S0,Baseline' + BASELINE_CONFIG_v1]"},"figures":[{"fig_id":"Fig2-1","title_en":"TTE vs Initial SOC (Baseline)","purpose":"Task 2: TTE vs. initial SOC z0 to quantify charge-level dependence.","plot_type":"line","x_axis":{"name":"Initial SOC z0","unit":null},"y_axis":{"name":"Time-to-Empty (TTE)","unit":"h"},"y2_axis":null,"data_fields":[{"field_name":"z0","meaning":"Initial state of charge values used for simulation runs","unit":null},{"field_name":"TTE_hours","meaning":"Predicted time-to-empty for each initial SOC","unit":"h"},{"field_name":"termination_reason","meaning":"Termination event causing shutdown (SOC_ZERO/V_CUTOFF/DELTA_ZERO)","unit":null}],"scenario_coverage_rule":"Baseline scenario only; include all z0 values appearing in TTE_TABLE_v1 (1.00, 0.75, 0.50, 0.25).","numeric_callouts_required":["TTE_hours at each z0 (tabulated or annotated)","TTE_hours at z0=1.00 (baseline headline value)","Observed termination_reason consistency across z0"],"source_locator":"[Source: Numerical Output (3); Keyword/Table/Section: TTE_TABLE_v1; Fields: z0,TTE_hours,termination_reason]","missing_data_policy":{"if_missing":"keep_stub_and_mark_unavailable","attempted_keywords":["TTE_TABLE_v1","z0,TTE_hours","termination_reason","TTE vs"]}},{"fig_id":"Fig2-2","title_en":"Scenario TTE Comparison (z0=1.00)","purpose":"Task 2: compare TTE across usage/environment scenarios to identify major drain drivers.","plot_type":"bar","x_axis":{"name":"Scenario ID","unit":null},"y_axis":{"name":"Time-to-Empty (TTE)","unit":"h"},"y2_axis":null,"data_fields":[{"field_name":"scenario_id","meaning":"Scenario identifier (S0..S7)","unit":null},{"field_name":"description","meaning":"Human-readable scenario description","unit":null},{"field_name":"TTE_hours","meaning":"Predicted TTE for each scenario (z0=1.00)","unit":"h"},{"field_name":"ΔTTE_hours","meaning":"TTE difference relative to baseline scenario S0","unit":"h"},{"field_name":"termination_reason","meaning":"Termination event per scenario","unit":null}],"scenario_coverage_rule":"All scenarios appearing in SCENARIO_TTE_TABLE_v1 (S0S7) at z0=1.00.","numeric_callouts_required":["Baseline TTE_hours (S0) and each scenario TTE_hours","Worst-case ΔTTE_hours (most negative) and its scenario_id","Any scenario with termination_reason != SOC_ZERO (e.g., V_CUTOFF)"],"source_locator":"[Source: Numerical Output (3); Keyword/Table/Section: SCENARIO_TTE_TABLE_v1; Fields: scenario_id,description,TTE_hours,ΔTTE_hours,termination_reason]","missing_data_policy":{"if_missing":"keep_stub_and_mark_unavailable","attempted_keywords":["SCENARIO_TTE_TABLE_v1","ΔTTE_hours","scenario_id","Baseline,4.60"]}},{"fig_id":"Fig2-3","title_en":"SOC Trajectory z(t) (Baseline)","purpose":"Task 2: mechanistic time-series showing discharge dynamics leading to TTE.","plot_type":"line","x_axis":{"name":"Time","unit":"s"},"y_axis":{"name":"State of Charge z(t)","unit":null},"y2_axis":null,"data_fields":[{"field_name":"t","meaning":"Simulation time grid","unit":"s"},{"field_name":"z","meaning":"State of charge trajectory","unit":null}],"scenario_coverage_rule":"Baseline scenario S0; at minimum include z0=1.00 trajectory (optionally overlay other z0 in TTE_TABLE_v1).","numeric_callouts_required":["Interpolated termination time t_star_sec (or TTE_seconds) for the displayed run(s)","Termination reason at t*"],"source_locator":"[Source: Numerical Output (3); Keyword/Table/Section: SIM_API_v1 OutputSchema.trajectory_columns includes t,z; FIGURE_SPEC_v1 plot 'State of Charge vs Time' uses columns t,z]","missing_data_policy":{"if_missing":"keep_stub_and_mark_unavailable","attempted_keywords":["trajectory","trajectory_columns","t, z","State of Charge vs Time","soc_v_time.png"]}},{"fig_id":"Fig2-4","title_en":"Current and Power vs Time","purpose":"Task 2: explain rapid drain via CPL-induced current escalation and power demand.","plot_type":"dual_axis_line","x_axis":{"name":"Time","unit":"s"},"y_axis":{"name":"Current I(t)","unit":"A"},"y2_axis":{"name":"Total Power P_tot(t)","unit":"W"},"data_fields":[{"field_name":"t","meaning":"Simulation time grid","unit":"s"},{"field_name":"I","meaning":"Discharge current from CPL closure","unit":"A"},{"field_name":"P_tot","meaning":"Total power demand from component mapping","unit":"W"}],"scenario_coverage_rule":"Baseline scenario S0; at minimum include z0=1.00 trajectory (optionally overlay key scenarios S4/S5 for contrast).","numeric_callouts_required":["avg_P_W over [0,t*] (baseline and/or compared scenarios)","max_I_A over [0,t*]","Identify time interval(s) of peak P_tot and corresponding usage segment (if segment labels available)"],"source_locator":"[Source: Numerical Output (3); Keyword/Table/Section: FIGURE_SPEC_v1 plot 'Current and Power vs Time' uses columns t,I,P_tot; TTE_TABLE_v1 provides avg_P_W and max_I_A]","missing_data_policy":{"if_missing":"keep_stub_and_mark_unavailable","attempted_keywords":["FIGURE_SPEC_v1","current_power_v_time.png","columns: t, I, P_tot","avg_P_W","max_I_A"]}},{"fig_id":"Fig2-5","title_en":"Battery Temperature Trajectory","purpose":"Task 2: show electro-thermal feedback and temperature-driven performance shifts.","plot_type":"line","x_axis":{"name":"Time","unit":"s"},"y_axis":{"name":"Battery Temperature T_b(t)","unit":"°C"},"y2_axis":null,"data_fields":[{"field_name":"t","meaning":"Simulation time grid","unit":"s"},{"field_name":"T_b","meaning":"Battery temperature trajectory (stored as T_b; convert to °C if stored in K)","unit":"K"}],"scenario_coverage_rule":"Baseline scenario S0; include at least z0=1.00 trajectory. For cold/hot scenarios, overlay S5/S6 if available.","numeric_callouts_required":["max_Tb_C over [0,t*] (baseline and/or compared scenarios)","Ambient temperature setting for the run (T_a_C or T_a in K)"],"source_locator":"[Source: Numerical Output (3); Keyword/Table/Section: FIGURE_SPEC_v1 plot 'Battery Temperature vs Time' uses columns t,T_b; TTE_TABLE_v1 provides max_Tb_C]","missing_data_policy":{"if_missing":"keep_stub_and_mark_unavailable","attempted_keywords":["temp_v_time.png","Battery Temperature vs Time","columns: t, T_b","max_Tb_C","T_a_C"]}},{"fig_id":"Fig2-6","title_en":"CPL Discriminant Delta Trajectory","purpose":"Task 2: diagnose proximity to power infeasibility/voltage-collapse via Δ(t).","plot_type":"line","x_axis":{"name":"Time","unit":"s"},"y_axis":{"name":"Discriminant Delta Δ(t)","unit":"V^2"},"y2_axis":null,"data_fields":[{"field_name":"t","meaning":"Simulation time grid","unit":"s"},{"field_name":"Delta","meaning":"CPL quadratic discriminant; Δ<=0 indicates infeasible power demand","unit":"V^2"},{"field_name":"V_term","meaning":"Terminal voltage (for contextual annotation when Δ is small)","unit":"V"}],"scenario_coverage_rule":"Baseline scenario S0; strongly recommended overlay for worst-case scenarios where cutoff shifts (e.g., S5 cold or S4 poor signal).","numeric_callouts_required":["min_Δ over [0,t*] (baseline and any stress scenarios)","If termination_reason=DELTA_ZERO or V_CUTOFF, annotate Δ and V_term near t*"],"source_locator":"[Source: Numerical Output (3); Keyword/Table/Section: FIGURE_SPEC_v1 plot 'Discriminant Delta vs Time' uses columns t,Delta; SIM_API_v1 OutputSchema includes Delta and V_term]","missing_data_policy":{"if_missing":"keep_stub_and_mark_unavailable","attempted_keywords":["delta_v_time.png","Discriminant Delta vs Time","columns: t, Delta","V_term","DELTA_ZERO"]}},{"fig_id":"Fig2-7","title_en":"UQ Survival Curve for TTE","purpose":"Task 2: quantify uncertainty in TTE predictions via empirical survival curve P(TTE>t).","plot_type":"survival_curve","x_axis":{"name":"Time","unit":"h"},"y_axis":{"name":"Survival Probability S(t)=P(TTE>t)","unit":null},"y2_axis":null,"data_fields":[{"field_name":"t_hours","meaning":"Time grid for survival curve evaluation","unit":"h"},{"field_name":"S(t)","meaning":"Empirical survival probability from Monte Carlo TTE samples","unit":null},{"field_name":"p10","meaning":"10th percentile of TTE distribution (survival crosses ~0.90)","unit":"h"},{"field_name":"p50","meaning":"Median TTE","unit":"h"},{"field_name":"p90","meaning":"90th percentile of TTE distribution (survival crosses ~0.10)","unit":"h"},{"field_name":"CI95_low","meaning":"Lower bound of 95% CI for mean TTE (normal approximation)","unit":"h"},{"field_name":"CI95_high","meaning":"Upper bound of 95% CI for mean TTE (normal approximation)","unit":"h"},{"field_name":"M","meaning":"Monte Carlo sample count","unit":null},{"field_name":"theta","meaning":"OU reversion rate used for usage-path perturbations","unit":"1/s"},{"field_name":"sigma","meaning":"OU diffusion scale used for usage-path perturbations","unit":null}],"scenario_coverage_rule":"Monte Carlo UQ for baseline scenario at z0=1.00 with M=300 paths (as reported).","numeric_callouts_required":["p10, p50, p90 TTE values","Mean TTE with 95% CI (CI95_low, CI95_high)","A survival milestone time (e.g., time at which S(t) first drops below 0.90)"],"source_locator":"[Source: Numerical Output (3); Keyword/Table/Section: UQ_SUMMARY_v1 + SURVIVAL_CURVE_v1 + REPRODUCIBILITY_v1; Fields: mean,std,p10,p50,p90,CI95_low,CI95_high,t_hours,S(t),M,theta,sigma,dt]","missing_data_policy":{"if_missing":"keep_stub_and_mark_unavailable","attempted_keywords":["UQ_SUMMARY_v1","SURVIVAL_CURVE_v1","t_hours,S(t)","REPRODUCIBILITY_v1","p10,p50,p90"]}}],"tables_required":["TableA_TTE_vs_z0","TableB_scenario_compare","TableC_driver_ranking","TableUQ_summary"],"traceability_rule":"All numerical values must include [Source: Numerical Output (3); Keyword/Table/Section: XXX]; if not found, state 'Not provided'—do not hallucinate."}}